AV blocks
AV dissociation (accelerated junctional rhythm)
The atria and ventricles beat independently, but because a lower pacemaker runs at least as fast as the sinus node, not because conduction is blocked. P waves drift in and out of the QRS complexes.

What the heart is doing
A junctional (or ventricular) pacemaker fires slightly faster than the sinus node. Each of its beats leaves the AV node refractory, so most sinus impulses arrive too soon to conduct; one that arrives late enough captures the ventricles.
Why it looks this way
This is AV dissociation because independent P waves march through a regular narrow rhythm that is faster than the atrial rate, and a well-timed P wave can still conduct.
Why it matters
A description, not a diagnosis: name the rhythm driving the ventricles and why the sinus node is slower. Unlike complete heart block, the AV node can still conduct, as capture beats prove. In a wide-complex tachycardia it strongly favors VT.
What to look for
- Compare the rates: here the QRS rate is faster than or equal to the P-wave rate.
- March out the P waves; they hide in the QRS, then reappear before or after it.
- Look for a capture beat: an early QRS after a P wave that lands well after the T wave.
Frequently asked questions
What are the ECG criteria for AV dissociation (accelerated junctional rhythm)?
Rates: ventricular rate equal to or faster than the atrial rate. Rhythm: QRS regular; P waves regular at their own rate. P waves: sinus P waves that move relative to the QRS. PR interval: varies; no fixed relationship. Capture beats: A well-timed P wave can conduct, arriving early.
How is AV dissociation (accelerated junctional rhythm) identified on an ECG?
This is AV dissociation because independent P waves march through a regular narrow rhythm that is faster than the atrial rate, and a well-timed P wave can still conduct.
What can AV dissociation (accelerated junctional rhythm) be mistaken for?
Third-degree AV block, junctional escape: the atrial rate is faster than the ventricular rate and no P wave ever conducts. Accelerated junctional rhythm: no independent sinus P waves. Wandering atrial pacemaker: P-wave shape changes and every P wave conducts.
What causes AV dissociation (accelerated junctional rhythm)?
Common causes: accelerated junctional rhythm (digoxin toxicity, after cardiac surgery, myocarditis); accelerated idioventricular rhythm after reperfusion; ventricular tachycardia; sinus slowing with a normal junctional escape; and high vagal tone.